Medium load
32.8%lower than the selected timer
Projected motor energy
Minimum modeled dissolved oxygen: 3.65 mg/L with SOLACE and 3.21 mg/L with the timer. Test threshold: 3.0 mg/L.
A shrimp pond aerator controller that adjusts aeration to oxygen demand before dawn.
Explore the pond controller or inspect the hardware assembly in the IMBNED team’s interactive viewer.
A timer runs the aerator on a fixed schedule. We designed dissolved-oxygen controls to respond to estimated pre-dawn demand. A solar panel and battery are part of the power design.
I led team IMBNED, coordinated hardware, control logic and proposal work, and represented the team at the Delta Cup regional final in Bangkok.
The September 19, 2026 tests used a physical motor and simulated pond conditions. Each run represented 12 hours of virtual night. Wh values project motor power over simulated time.
lower than the selected timer
Minimum modeled dissolved oxygen: 3.65 mg/L with SOLACE and 3.21 mg/L with the timer. Test threshold: 3.0 mg/L.
lower than the selected timer
Minimum modeled dissolved oxygen: 3.63 mg/L with SOLACE and 3.18 mg/L with the timer. Test threshold: 3.0 mg/L.
Light load
With initial oxygen at 6.2 mg/L, the pond model stayed above 3.0 mg/L overnight without scheduled aeration. This scenario has no comparable savings percentage.
We screened 20 timer settings per scenario, including off. For physical motor trials, we selected the lowest-energy schedule that met the oxygen threshold in the model. The selected timer ran at 22:00 for one hour under medium load and two hours under high load.
Power was measured with a motor current sensor. Oxygen came from the model. The chart projects energy over virtual time. Full-system electricity use and performance in a real pond still require testing.
Sample data · 12 hours
Scrub through the night to compare motor power and dissolved oxygen. Both curves are illustrative and separate from the SOLACE test results above.
I led IMBNED, designed the PCB, and developed the firmware and control logic. I also prepared the proposal and presented the partial prototype in Bangkok.
The architecture combines an ESP32-S3, dissolved oxygen measurements and aeration scheduling based on solar availability. In an illustrative 48-hour scenario, the model kept oxygen above 3.0 mg/L.
VirtualPond recorded physical pump and current measurements against virtual pond, battery and solar conditions. Six accelerated hardware-in-the-loop tests took about 145–220 seconds each. Two other comparison scenarios missed the 60% savings target against the best timer. Field validation remains open.